What might delamination of the roof sheathing lead to.
May lead to delamination of the roof sheathing.
But probably not due to the amount of delamination.
One of the implications of high moisture levels from either condensation or leakage is delamination of plywood sheathing.
When the membrane and insulation separate.
Every re roof requires a close inspection of the substrate.
The horizontal board enclosing the ends of the rafter projections or tails is normally referred to as the board.
If the environment is humid moisture can get trapped between the membrane and insulation.
To improve it make sure your home has continuous ridge and soffit ventilation.
That being said what the home inspector saw may or may not be mold.
This winter i went up.
The contractor thought it might have been due to excess moisture in the attic.
Depression between the rafters.
Like blisters delamination can come from improper installation in inclement weather.
Panel type roof sheathing may lift off the rafters in a regular pattern.
This may be indicative of what.
High moisture levels break down the glue in the plywood and allow the plies to delaminate.
What is the spacing requirements between the insulation and the roof deck sheathing at the location of the vent.
Delaminations commonly affect single ply and fully adhered roofs.
In the attic the roof sheathing appears to be delaminating and some staining was observed.
Leaks around deteriorated flashing are the most common.
Between the years of around 1964 to 1975 homes being built saw the installation of what was first generation fire retardant plywood.
Defects in those sheets or it could be that the ventilation was blocked only at those sheets.
The attic was vented by soffit and a ridge vents.
If this is the case the solution is twofold.
3 8 plywood roof sheathing.
First deal with the cause which is inadequate attic ventilation.
It may be mfgr.
In determining if it is.
Incidental roof leaks particularly ones that go unnoticed can delaminate plywood sheathing or cause osb to swell.
De lamination of the roof sheathing may cause.
In the future looking for a date stamp on the affected sheet or other sheets in the same general area may help an apa rep.
The soffits didn t appear to be congested with insulation however the ridge vent had a filter in place.
It more likely may be the early stages of decay and delamination of the roof sheathing.
Roof decking plywood delamination if you have a home twenty five years or older you may want to consider the condition of the plywood.
The worst cases result in patches of rot.
It was plywood and had delaminated.